MEAN WELL
SP-240-30
Single-output switch-mode power supply unit (SMPS PSU) with PFC function - Meanwell (SP-240) - output voltage 30Vdc - Output current 8A - Rated power 240W - Input voltage 88-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -20…+70°C ambient - 1-output
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
SP-240-30
Online Price
$ 102.35
Discount
3.0%
Net Price
$ 99.28
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
SP-240-30Meanwell - SP-240
Description
Single-output switch-mode power supply unit (SMPS PSU) with PFC function - Meanwell (SP-240) - output voltage 30Vdc - Output current 8A - Rated power 240W - Input voltage 88-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -20…+70°C ambient - 1-output
Additional Information
MEAN WELL PFC ENABLED
Specifications
Primary brand
Meanwell
Main function
Power supply unit
Product series / family name
Enclosed-PFC
Sub-range name
SP-240
Functions
Single-output switch-mode power supply unit (SMPS PSU) with PFC function
1-output
1-output
Supply voltage (AC)
88-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.)
Supply voltage (DC)
124-370Vdc (127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Type of network
Single phase
Rated current
8A
Rated power
240W
Output voltage (DC)
25.5Vdc-34.5Vdc (adjustable range)
30Vdc
30Vdc
Protection functions
Short-circuit
Over load (Hiccup mode; auto-recovery)
Over voltage (Shut off; AC recycle to re-start)
Over temperature
Over load (Hiccup mode; auto-recovery)
Over voltage (Shut off; AC recycle to re-start)
Over temperature
Protection settings
Over load (105-135%)
Over voltage (120-150%)
Over voltage (120-150%)
Efficiency
0.88
Ambient air temperature for operation
-20…+70 °C
Current consumption
(inrush; 230Vac) 40 A
Manufacturer product status
Commercialized
Compliant with standard(s)
UL60950-1
IEC60950-1
IEC55014
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC60950-1
IEC55014
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
Accuracy class
0.01
Ripple
150mV
Minimum temperature
-20 °C
Maximum temperature
70 °C
Related Documents
Name | Last Update | Language |
---|---|---|
Meanwell - SP-240 - Datasheet | 02 Oct 2017 | English (US) |