MEAN WELL
RSP-500-3.3
Single-output power supply unit (PSU) with PFC function - Meanwell (RSP-500) - output voltage 3.3Vdc - Output current 90A - Rated power 500W - Input voltage 85-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -30…+70°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
RSP-500-3.3
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
RSP-500-3.3Meanwell - RSP-500
Description
Single-output power supply unit (PSU) with PFC function - Meanwell (RSP-500) - output voltage 3.3Vdc - Output current 90A - Rated power 500W - Input voltage 85-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -30…+70°C ambient
Additional Information
MEAN WELL PFC & PARALLEL ENABLED
Specifications
Primary brand
Meanwell
Main function
Power supply unit
Product series / family name
Enclosed-PFC
Sub-range name
RSP-500
Functions
Single-output power supply unit (PSU) with PFC function
Supply voltage (AC)
85-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.)
Supply voltage (DC)
120-370Vdc (120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Type of network
Single phase
Rated current
90A
Rated power
500W
Shape
Low profile
Output voltage (DC)
2.97Vdc-3.63Vdc (adjustable range)
3.3Vdc
3.3Vdc
Protection functions
Short-circuit
Over load (Constant current limiting; auto-recovery)
Over voltage (Shut down O/P voltage; re-power on to recover)
Over temperature
Over load (Constant current limiting; auto-recovery)
Over voltage (Shut down O/P voltage; re-power on to recover)
Over temperature
Protection settings
Over load (105-130%)
Over voltage (115-145%)
Over voltage (115-145%)
Efficiency
0.81
Ambient air temperature for operation
-30…+70 °C
Current consumption
(inrush; 230Vac) 40 A
Manufacturer product status
Commercialized
Compliant with standard(s)
UL60950-1
IEC60950-1
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC61000-6-2
IEC60950-1
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC61000-6-2
Accuracy class
0.02
Ripple
120mV
Minimum temperature
-30 °C
Maximum temperature
70 °C
Related Documents
Name | Last Update | Language |
---|---|---|
Meanwell - RSP-500 - Datasheet | 02 Oct 2017 | English (US) |