MEAN WELL
PT-65A
Triple output switch-mode power supply unit (SMPS PSU) - Meanwell (PT-65) - output voltage (output 1 nom.) 5Vdc / (output 2 nom.) 12Vdc / (output 3 nom.) 5Vdc - Output current 0.4-7A (output 1) / 0.2-3.2A (output 2) / 0.7A (output 3) - Rated power 65W / 60W (maximum) - Input voltage 90-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -10…+60°C ambient - 3-outputs
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PT-65A
Online Price
$ 39.10
Discount
3.0%
Net Price
$ 37.93
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
PT-65AMeanwell - PT-65
Description
Triple output switch-mode power supply unit (SMPS PSU) - Meanwell (PT-65) - output voltage (output 1 nom.) 5Vdc / (output 2 nom.) 12Vdc / (output 3 nom.) 5Vdc - Output current 0.4-7A (output 1) / 0.2-3.2A (output 2) / 0.7A (output 3) - Rated power 65W / 60W (maximum) - Input voltage 90-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.) (Single phase) - Rated for -10…+60°C ambient - 3-outputs
Additional Information
MEAN WELL OPEN FRAME UNIT
Specifications
Primary brand
Meanwell
Main function
Power supply unit
Product series / family name
Open Frame
Sub-range name
PT-65
Functions
Triple output switch-mode power supply unit (SMPS PSU)
3-outputs
3-outputs
Supply voltage (AC)
90-264Vac (100Vac / 110Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.)
Supply voltage (DC)
127-370Vdc (127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Type of network
Single phase
Rated current
0.4-7A (output 1)
0.2-3.2A (output 2)
0.7A (output 3)
0.2-3.2A (output 2)
0.7A (output 3)
Rated power
65W
60W (maximum)
60W (maximum)
Output voltage (DC)
(output 1) 4.75Vdc-5.50Vdc (adjustable range)
(output 1 nom.) 5Vdc
(output 2) 11.4-13.2Vdc (adjustable range)
(output 2 nom.) 12Vdc
(output 3) 5.25-4.50Vdc (adjustable range)
(output 3 nom.) 5Vdc
(output 1 nom.) 5Vdc
(output 2) 11.4-13.2Vdc (adjustable range)
(output 2 nom.) 12Vdc
(output 3) 5.25-4.50Vdc (adjustable range)
(output 3 nom.) 5Vdc
Protection functions
Short-circuit
Over load (Hiccup mode; auto-recovery)
Over voltage (Rated output voltage)
Over load (Hiccup mode; auto-recovery)
Over voltage (Rated output voltage)
Protection settings
Over load (73-105W)
Over voltage (115-135%)
Over voltage (115-135%)
Efficiency
0.76
Leakage current
0-0.75 mA
Ambient air temperature for operation
-10…+60 °C
Current consumption
(inrush; 115Vac) 20 A
(inrush; 230Vac) 40 A
(inrush; 230Vac) 40 A
Manufacturer product status
Commercialized
Compliant with standard(s)
UL60950-1
IEC60950-1
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC60950-1
IEC55022
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
Accuracy class
(output 1) 4.0%
(output 2) 7.0%
(output 3) 5.0%
(output 2) 7.0%
(output 3) 5.0%
Ripple
(output 1) 50mV
(output 2) 120mV
(output 3) 50mV
(output 2) 120mV
(output 3) 50mV
Minimum temperature
-10 °C
Maximum temperature
60 °C
Hold time
(full load; 230Vac) 0.06 s